Datenbank
0007-D-Puncture analysis for a compact foundation
The example was created by
and published on 05.10.2017 on
published. You can find it at https://evadat.com/de/bsp/0007/.
D0Classification
- ClassD · Standards-based verification example
- Structural system typeSpecial component
- MechanicsOther
- Material lawOther material laws
- MaterialConcrete/reinforced concrete/prestressed concrete
- Verification formatUltimate limit state verification
- StandardDIN EN 1992
D1Problem description
For a centrally loaded, compact foundation, the punching shear verification shall be carried out in accordance with DIN EN 1992-1-1. The load, the dimensions and the existing reinforcement are shown in Fig. D1-1 and Tab. D1-1.
Geometry | Material properties | Load |
|---|---|---|
hcol,x = 0.40 m | fck = 20 N/mm² | Ng,k = 1437 kN |
Für ein zentrisch belastetes gedrungenes Fundament soll der Durchstanznachweis nach DIN EN 1992-1-1 geführt werden. Die Belastung, die Abmessungen sowie die vorhandene Bewehrung sind Abb. D1-1 und Tab. D1-1 zu entnehmen.
Geometrie | Materialeigenschaften | Belastung |
|---|---|---|
hcol,x = 0,40 m | fck = 20 N/mm2 | Ng,k = 1437 kN |